Category: I/O systems > X20 System > System modules for bus controllers
Supply for the bus controller, X2X Link and internal I/O supply Low-cost supply module for small X20 system Feed and bus controller / X2X Link supply not electrically isolated Expansion or redundancy of bus controller / X2X Link supply not possible by operating multiple supply modules simultaneously The supply module is used together with an X20 bus controller.
It is equipped with a feed for the bus controller, the X2X Link and the internal I/O supply.
The module is designed to supply power for smaller X20 systems. Potential groups are able to be formed.
An expansion or redundancy of the X2X Link with the X20PS3300 or X20PS3310 supply module is not possible.
Expansion of the X20 system with a bus transmitter is not permitted either.
Technical Specifications
Short description
- Power supply module = 24 VDC supply module for bus controller, X2X Link power supply and I/O
General information
- Diagnostics
- Module run/error = Yes, using LED status indicator and software
- Overload = Yes, using LED status indicator and software
- Power consumption
- Internal I/O = 0.6 W
- Certifications
- CE = Yes
- UKCA = Yes
- CRA (Cyber Resilience Act) = In preparation
- ATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X
- UL = cULus E115267 Industrial control equipment
- HazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
- DNV = Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)
- CCS = Yes
- LR = ENV1
- KR = Yes
- ABS = Yes
- BV = EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck
- KC = Yes
- B&R ID code = 0xA389
- Status indicators = Operating state, module status
- Power consumption for X2X Link power supply = 1.64 W
- Additional power dissipation caused by actuators (resistive) [W] = -
Bus controller / X2X Link power supply input
- Input voltage = 24 VDC -15% / +20%
- Input current = Max. 0.7 A
- Fuse = Integrated, cannot be replaced
- Reverse polarity protection = Yes
Bus controller / X2X Link power supply output
- Nominal output power
- Horizontal mounting orientation = 7 W at 45°C and 5 W at 55°C
- Vertical mounting orientation = 7 W at 40°C and 5 W at 50°C
- Parallel connection = No
- Redundant operation = No
- Overload characteristics = Short-circuit proof, temporary overload
Input I/O power supply
- Input voltage = 24 VDC -15% / +20%
- Fuse = Required line fuse: Max. 10 A, slow-blow
- Reverse polarity protection = No
Output I/O power supply
- Nominal output voltage = 24 VDC
- Behavior on short circuit = Required line fuse
- Permissible contact load = 10 A
Electrical properties
- Electrical isolation = BC/X2X Link supply not isolated from BC/X2X Link power supply, and I/O supply not isolated from I/O power supply
Operating conditions
- Mounting orientation
- Horizontal = Yes
- Vertical = Yes
- Installation elevation above sea level
- 0 to 2000 m = No limitation
- >2000 m = Reduction of ambient temperature by 0.5°C per 100 m
- Degree of protection per EN 60529 = IP20
Ambient conditions
- Temperature
- Operation
- Horizontal mounting orientation = -25 to 60°C
- Vertical mounting orientation = -25 to 50°C
- Derating = See section "Derating".
- Storage = -40 to 85°C
- Transport = -40 to 85°C
- Relative humidity
- Operation = 5 to 95%, non-condensing
- Storage = 5 to 95%, non-condensing
- Transport = 5 to 95%, non-condensing
Mechanical properties
- Note = Order 1x terminal block X20TB12 separately. Order 1x bus base X20BB8x separately.
- Pitch = 12.5 +0.2 mm