Category: I/O systems > X20 System > Temperature measurement

2 inputs for resistance temperature measurement For PT100 and PT1000 Configurable sensor type per channel Direct resistance measurement Configurable 2- or 3- wire connections per module Configurable filter time The module is equipped with 2 inputs for PT100/PT1000 resistance temperature measurement.

This module is designed for X20 6-pin terminal blocks. If needed (e.g.

for logistical reasons), the 12-pin terminal block can also be used.

Technical Specifications

Short description

  • I/O module = 2 inputs for Pt100 or Pt1000 resistance temperature measurement

General information

  • Diagnostics
  • Module run/error = Yes, using LED status indicator and software
  • Inputs = Yes, using LED status indicator and software
  • Power consumption
  • Bus = 0.01 W
  • Internal I/O = 1.1 W
  • Certifications
  • CE = Yes
  • UKCA = Yes
  • CRA (Cyber Resilience Act) = In preparation
  • ATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X
  • UL = cULus E115267 Industrial control equipment
  • HazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
  • DNV = Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)
  • CCS = Yes
  • LR = ENV1
  • KR = Yes
  • ABS = Yes
  • BV = EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck
  • KC = Yes
  • B&R ID code = 0x1BA6
  • Status indicators = I/O function per channel, operating state, module status
  • Additional power dissipation caused by actuators (resistive) [W] = -

Resistance measurement temperature inputs

  • Conversion time
  • 1 channel = 20 ms with 50 Hz filter
  • 2 channels = 80 ms with 50 Hz filter
  • Sensor
  • Sensor type = Configurable per channel
  • Pt100 = -200 to 850°C
  • Pt1000 = -200 to 850°C
  • Max. error at 25°C
  • Gain = ±0.037%
  • Offset = ±0.0015%
  • Temperature sensor resolution
  • Pt100 = 1 LSB = 0.1°C
  • Pt1000 = 1 LSB = 0.1°C
  • Resistance measurement resolution
  • G = 1 = 0.1 Ω
  • G = 2 = 0.05 Ω
  • Common-mode rejection
  • 50 Hz = >80 dB
  • DC = >95 dB
  • Standardized range of values for resistance measurement
  • G = 1 = 0.1 to 4500 Ω
  • G = 2 = 0.05 to 2250 Ω
  • Temperature sensor normalization
  • Pt100 = -200.0 to 850.0°C
  • Pt1000 = -200.0 to 850.0°C
  • Temperature measurement monitoring
  • Range undershoot = 0x8001
  • Range overshoot = 0x7FFF
  • Open circuit = 0x7FFF
  • General fault = 0x8000
  • Open inputs = 0x7FFF
  • Resistance measurement monitoring
  • Range overshoot = 0xFFFF
  • Open circuit = 0xFFFF
  • General fault = 0xFFFF
  • Open inputs = 0xFFFF
  • Input = Resistance measurement with constant current supply for 2- or 3-wire connections
  • Digital converter resolution = 16-bit
  • Filter time = Configurable between 1 ms and 66.7 ms
  • Conversion procedure = Sigma-delta
  • Output format = INT or UINT for resistance measurement
  • Resistance measurement range = 0.1 to 4500 Ω / 0.05 to 2250 Ω
  • Input filter = First-order low-pass filter / cutoff frequency 500 Hz
  • Sensor standard = EN 60751
  • Common-mode range = >0.7 V
  • Insulation voltage between channel and bus = 500 V eff
  • Linearization method = Internal
  • Measuring current = 250 µA ±1.25%
  • Reference = 4530 Ω ±0.1%
  • Permissible input signal = Short-term max. ±30 V
  • Max. gain drift = ±0.004%/°C
  • Max. offset drift = ±0.00015%/°C
  • Nonlinearity = <0.001%
  • Crosstalk between channels = <-93 dB

Electrical properties

  • Electrical isolation = Channel isolated from bus Channel not isolated from channel

Operating conditions

  • Mounting orientation
  • Horizontal = Yes
  • Vertical = Yes
  • Installation elevation above sea level
  • 0 to 2000 m = No limitation
  • >2000 m = Reduction of ambient temperature by 0.5°C per 100 m
  • Degree of protection per EN 60529 = IP20

Ambient conditions

  • Temperature
  • Operation
  • Horizontal mounting orientation = -25 to 60°C
  • Vertical mounting orientation = -25 to 50°C
  • Derating = -
  • Storage = -40 to 85°C
  • Transport = -40 to 85°C
  • Relative humidity
  • Operation = 5 to 95%, non-condensing
  • Storage = 5 to 95%, non-condensing
  • Transport = 5 to 95%, non-condensing

Mechanical properties

  • Note = Order 1x terminal block X20TB06 or X20TB12 separately. Order 1x bus module X20BM11 separately.
  • Pitch = 12.5 +0.2 mm

Place your order before 14:00 for earliest possible shipment handover. With round-the-clock transit operated by our partnered global logistics providers, parcels reach most international destinations following routine customs processing. Normal delivery takes 2–6 business days subject to customs clearance progress.Shipping fees will be charged for all orders under USD 500, and the exact shipping cost will be determined and collected by our logistics carriers. Shipments to remote international regions will incur additional courier surcharges to offset extra cross-border transportation costs.