{"product_id":"b-r-x20at2222","title":"B\u0026R X20AT2222","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e I\/O systems \u0026gt; X20 System \u0026gt; Temperature measurement\u003c\/p\u003e\n\u003cp\u003e2 inputs for resistance temperature measurement For PT100 and PT1000 Configurable sensor type per channel Direct resistance measurement Configurable 2- or 3- wire connections per module Configurable filter time The module is equipped with 2 inputs for PT100\/PT1000 resistance temperature measurement.\u003c\/p\u003e\n\u003cp\u003eThis module is designed for X20 6-pin terminal blocks. If needed (e.g.\u003c\/p\u003e\n\u003cp\u003efor logistical reasons), the 12-pin terminal block can also be used.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eI\/O module = 2 inputs for Pt100 or Pt1000 resistance temperature measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eModule run\/error = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eInputs = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eBus = 0.01 W\u003c\/li\u003e\n\u003cli\u003eInternal I\/O = 1.1 W\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eDNV = Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)\u003c\/li\u003e\n\u003cli\u003eCCS = Yes\u003c\/li\u003e\n\u003cli\u003eLR = ENV1\u003c\/li\u003e\n\u003cli\u003eKR = Yes\u003c\/li\u003e\n\u003cli\u003eABS = Yes\u003c\/li\u003e\n\u003cli\u003eBV = EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x1BA6\u003c\/li\u003e\n\u003cli\u003eStatus indicators = I\/O function per channel, operating state, module status\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W] = -\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eResistance measurement temperature inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConversion time\u003c\/li\u003e\n\u003cli\u003e1 channel = 20 ms with 50 Hz filter\u003c\/li\u003e\n\u003cli\u003e2 channels = 80 ms with 50 Hz filter\u003c\/li\u003e\n\u003cli\u003eSensor\u003c\/li\u003e\n\u003cli\u003eSensor type = Configurable per channel\u003c\/li\u003e\n\u003cli\u003ePt100 = -200 to 850°C\u003c\/li\u003e\n\u003cli\u003ePt1000 = -200 to 850°C\u003c\/li\u003e\n\u003cli\u003eMax. error at 25°C\u003c\/li\u003e\n\u003cli\u003eGain = ±0.037%\u003c\/li\u003e\n\u003cli\u003eOffset = ±0.0015%\u003c\/li\u003e\n\u003cli\u003eTemperature sensor resolution\u003c\/li\u003e\n\u003cli\u003ePt100 = 1 LSB = 0.1°C\u003c\/li\u003e\n\u003cli\u003ePt1000 = 1 LSB = 0.1°C\u003c\/li\u003e\n\u003cli\u003eResistance measurement resolution\u003c\/li\u003e\n\u003cli\u003eG = 1 = 0.1 Ω\u003c\/li\u003e\n\u003cli\u003eG = 2 = 0.05 Ω\u003c\/li\u003e\n\u003cli\u003eCommon-mode rejection\u003c\/li\u003e\n\u003cli\u003e50 Hz = \u0026gt;80 dB\u003c\/li\u003e\n\u003cli\u003eDC = \u0026gt;95 dB\u003c\/li\u003e\n\u003cli\u003eStandardized range of values for resistance measurement\u003c\/li\u003e\n\u003cli\u003eG = 1 = 0.1 to 4500 Ω\u003c\/li\u003e\n\u003cli\u003eG = 2 = 0.05 to 2250 Ω\u003c\/li\u003e\n\u003cli\u003eTemperature sensor normalization\u003c\/li\u003e\n\u003cli\u003ePt100 = -200.0 to 850.0°C\u003c\/li\u003e\n\u003cli\u003ePt1000 = -200.0 to 850.0°C\u003c\/li\u003e\n\u003cli\u003eTemperature measurement monitoring\u003c\/li\u003e\n\u003cli\u003eRange undershoot = 0x8001\u003c\/li\u003e\n\u003cli\u003eRange overshoot = 0x7FFF\u003c\/li\u003e\n\u003cli\u003eOpen circuit = 0x7FFF\u003c\/li\u003e\n\u003cli\u003eGeneral fault = 0x8000\u003c\/li\u003e\n\u003cli\u003eOpen inputs = 0x7FFF\u003c\/li\u003e\n\u003cli\u003eResistance measurement monitoring\u003c\/li\u003e\n\u003cli\u003eRange overshoot = 0xFFFF\u003c\/li\u003e\n\u003cli\u003eOpen circuit = 0xFFFF\u003c\/li\u003e\n\u003cli\u003eGeneral fault = 0xFFFF\u003c\/li\u003e\n\u003cli\u003eOpen inputs = 0xFFFF\u003c\/li\u003e\n\u003cli\u003eInput = Resistance measurement with constant current supply for 2- or 3-wire connections\u003c\/li\u003e\n\u003cli\u003eDigital converter resolution = 16-bit\u003c\/li\u003e\n\u003cli\u003eFilter time = Configurable between 1 ms and 66.7 ms\u003c\/li\u003e\n\u003cli\u003eConversion procedure = Sigma-delta\u003c\/li\u003e\n\u003cli\u003eOutput format = INT or UINT for resistance measurement\u003c\/li\u003e\n\u003cli\u003eResistance measurement range = 0.1 to 4500 Ω \/ 0.05 to 2250 Ω\u003c\/li\u003e\n\u003cli\u003eInput filter = First-order low-pass filter \/ cutoff frequency 500 Hz\u003c\/li\u003e\n\u003cli\u003eSensor standard = EN 60751\u003c\/li\u003e\n\u003cli\u003eCommon-mode range = \u0026gt;0.7 V\u003c\/li\u003e\n\u003cli\u003eInsulation voltage between channel and bus = 500 V eff\u003c\/li\u003e\n\u003cli\u003eLinearization method = Internal\u003c\/li\u003e\n\u003cli\u003eMeasuring current = 250 µA ±1.25%\u003c\/li\u003e\n\u003cli\u003eReference = 4530 Ω ±0.1%\u003c\/li\u003e\n\u003cli\u003ePermissible input signal = Short-term max. ±30 V\u003c\/li\u003e\n\u003cli\u003eMax. gain drift = ±0.004%\/°C\u003c\/li\u003e\n\u003cli\u003eMax. offset drift = ±0.00015%\/°C\u003c\/li\u003e\n\u003cli\u003eNonlinearity = \u0026lt;0.001%\u003c\/li\u003e\n\u003cli\u003eCrosstalk between channels = \u0026lt;-93 dB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation = Channel isolated from bus Channel not isolated from channel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting orientation\u003c\/li\u003e\n\u003cli\u003eHorizontal = Yes\u003c\/li\u003e\n\u003cli\u003eVertical = Yes\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003e0 to 2000 m = No limitation\u003c\/li\u003e\n\u003cli\u003e\u0026gt;2000 m = Reduction of ambient temperature by 0.5°C per 100 m\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eHorizontal mounting orientation = -25 to 60°C\u003c\/li\u003e\n\u003cli\u003eVertical mounting orientation = -25 to 50°C\u003c\/li\u003e\n\u003cli\u003eDerating = -\u003c\/li\u003e\n\u003cli\u003eStorage = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eTransport = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eTransport = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNote = Order 1x terminal block X20TB06 or X20TB12 separately. Order 1x bus module X20BM11 separately.\u003c\/li\u003e\n\u003cli\u003ePitch = 12.5 +0.2 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":70970906050813,"sku":"X20AT2222","price":594.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20AT2222.right-33076cd4.jpg?v=1785317953","url":"https:\/\/shanghailianyou.com\/products\/b-r-x20at2222","provider":"Lianyou PLC","version":"1.0","type":"link"}