{"product_id":"b-r-8bvp0220hw00-000-1","title":"B\u0026R 8BVP0220HW00.000-1","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmulti \u0026gt; Power supply modules \u0026gt; Wall mounting\u003c\/p\u003e\n\u003cp\u003eWide input voltage range Capable of regeneration Integrated connection for temperature sensors 2 slots for ACOPOSmulti plug-in modules ACOPOSmulti power supply module, 22 A, AS, wall mounting.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport\u003c\/li\u003e\n\u003cli\u003eDynamic node allocation (DNA) = Yes\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Evaluation ongoing\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xA7CF\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Wall mounting\u003c\/li\u003e\n\u003cli\u003eSlots for plug-in modules = 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMains connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMax. chargeable DC bus capacitance depending on mains voltage\u003c\/li\u003e\n\u003cli\u003e230 VAC = 17.4 mF\u003c\/li\u003e\n\u003cli\u003e400 VAC = 5.8 mF\u003c\/li\u003e\n\u003cli\u003e480 VAC = 4 mF\u003c\/li\u003e\n\u003cli\u003eVariant\u003c\/li\u003e\n\u003cli\u003eL1, L2, L3, PE = Connector\u003c\/li\u003e\n\u003cli\u003ePE = M5 threaded bolt\u003c\/li\u003e\n\u003cli\u003eShield connection = Yes\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.5 to 16 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 20 to 6 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 20 to 6 AWG\u003c\/li\u003e\n\u003cli\u003eNetwork configurations = TT, TN-S, TN-C-S\u003c\/li\u003e\n\u003cli\u003eMains input voltage = 3x 220 to 3x 480 VAC ±10%\u003c\/li\u003e\n\u003cli\u003eFrequency = 50 \/ 60 Hz ±4%\u003c\/li\u003e\n\u003cli\u003eInstalled load = Max. 15.6 kW\u003c\/li\u003e\n\u003cli\u003eInrush current at 400 VAC = Max. 67 A\u003c\/li\u003e\n\u003cli\u003eSwitch-on interval = \u0026gt;300 s\u003c\/li\u003e\n\u003cli\u003eNominal switching frequency = 5 kHz\u003c\/li\u003e\n\u003cli\u003ePossible switching frequencies = 5 \/ 10 kHz\u003c\/li\u003e\n\u003cli\u003eIntegrated line filter per EN 61800-3, category C3 = No\u003c\/li\u003e\n\u003cli\u003eIntegrated regeneration choke = No\u003c\/li\u003e\n\u003cli\u003eRegenerative = Yes\u003c\/li\u003e\n\u003cli\u003ePower factor correction (PFC) = Yes\u003c\/li\u003e\n\u003cli\u003eLine fuse = Max. 66 A (gG fuses per IEC 60269-1 or Class CC, J, T) Max. 55 A (circuit breaker per EN 60947-2 or UL 489)\u003c\/li\u003e\n\u003cli\u003eTerminal cable cross section dimension of shield connection = 23 to 35 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eNominal = 750 VDC\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on mains input voltage\u003c\/li\u003e\n\u003cli\u003eMains input voltage \u0026lt;3x 400 VAC = 37.5 W\/V * (400 V - Mains input voltage)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on DC bus voltage (U DC )\u003c\/li\u003e\n\u003cli\u003eU DC \u0026lt;750 VDC = P * (1 - U DC \/750)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = 0.27 kW\/K (starting at 31°C)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 1.5 kW per 1000 m\u003c\/li\u003e\n\u003cli\u003eReduction of peak power depending on mains input voltage\u003c\/li\u003e\n\u003cli\u003eMains input voltage \u0026lt;3x 400 VAC = 94 W\/V * (400 V - Mains input voltage)\u003c\/li\u003e\n\u003cli\u003ePower dissipation depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = [0.28*P²+7.9*P+40] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = [0.9*P²+5.3*P+110] W\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = No\u003c\/li\u003e\n\u003cli\u003eContinuous power (supply and regeneration) = 15 kW\u003c\/li\u003e\n\u003cli\u003ePeak power (supply and regeneration) = 37.5 kW\u003c\/li\u003e\n\u003cli\u003eDC bus capacitance = 495 µF\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 25 VDC ±1.6%\u003c\/li\u003e\n\u003cli\u003eInput capacitance = 4.7 µF\u003c\/li\u003e\n\u003cli\u003eMax. power consumption = 27 W + P SLOT1 + P SLOT2 + P 24 V Out + P Fan8BVF...\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC Out\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 260 to 315 VDC = 25 VDC * (U DC \/ 315)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 315 to 800 VDC = 24 VDC ±6%\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eFuse protection = 250 mA (slow-blow) electronic, automatic reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFilter fan connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = No\u003c\/li\u003e\n\u003cli\u003eShort-circuit proof = Yes\u003c\/li\u003e\n\u003cli\u003eOpen-circuit monitoring = No\u003c\/li\u003e\n\u003cli\u003eUndervoltage monitoring = No\u003c\/li\u003e\n\u003cli\u003eOutput voltage = 24 V +5.8% \/ -0.1%\u003c\/li\u003e\n\u003cli\u003eContinuous current = 4.2 A\u003c\/li\u003e\n\u003cli\u003eMax. overcurrent limiting = 10 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrigger inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - Power supply module = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003eRising edge = 52 μs ±0.5 μs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eFalling edge = 53 μs ±0.5 μs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 10 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":70970905592061,"sku":"8BVP0220HW00.000-1","price":12541.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8BVP0220HW00.000-1.right-6b20c0fd_7e99d686-8591-4dfa-9c25-41df4ce22d71.jpg?v=1785317872","url":"https:\/\/shanghailianyou.com\/products\/b-r-8bvp0220hw00-000-1","provider":"Lianyou PLC","version":"1.0","type":"link"}